Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 23
1.
Innovations (Phila) ; 19(2): 156-160, 2024.
Article En | MEDLINE | ID: mdl-38462836

OBJECTIVE: Here we report our preclinical, proof-of-concept testing to assess the ability of a novel device to correct mitral regurgitation. The Milwaukee Heart device aims to enable any cardiac surgeon to perform high-quality mitral valve repair using a standard annuloplasty ring with a crosshatch of microporous, monofilament suture. METHODS: Hemodynamic, echocardiographic, and videographic data were collected at baseline, following induction of mitral regurgitation, and after repair using porcine hearts in an ex vivo biosimulator model. A commercially available cardiac prosthesis assessment platform was then used to assess the hydrodynamic characteristics of the study device. RESULTS: Porcine biosimulator pressure and flow metrics exhibited successful correction of mitral regurgitation following device implantation with similar values to baseline. Hydrodynamic results yielded pressure gradients and an effective orifice area comparable to currently approved prostheses. CONCLUSIONS: The study device effectively reduced mitral valve regurgitation and improved hemodynamics in our preclinical model with similar biophysical metrics to currently approved devices. Future in vivo trials are needed to evaluate the efficacy, biocompatibility, and freedom from the most likely adverse events, such as device thrombosis, embolic events, and hemolysis.


Heart Valve Prosthesis , Hemodynamics , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Proof of Concept Study , Animals , Mitral Valve Annuloplasty/methods , Mitral Valve Annuloplasty/instrumentation , Swine , Mitral Valve Insufficiency/surgery , Hemodynamics/physiology , Prosthesis Design , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Echocardiography , Disease Models, Animal
2.
Biomedicines ; 11(7)2023 Jun 25.
Article En | MEDLINE | ID: mdl-37509457

Background: Coarctation of the aorta (CoA; constriction of the proximal descending thoracic aorta) is among the most common congenital cardiovascular defects. Coarctation-induced mechanical perturbations trigger a cycle of mechano-transduction events leading to irreversible precursors of hypertension including arterial thickening, stiffening, and vasoactive dysfunction in proximal conduit arteries. This study sought to identify kinetics of the stress-mediated compensatory response leading to these alterations using a preclinical rabbit model of CoA. Methods: A prior growth and remodeling (G&R) framework was reformulated and fit to empirical measurements from CoA rabbits classified into one control and nine CoA groups of various severities and durations (n = 63, 5-11/group). Empirical measurements included Doppler ultrasound imaging, uniaxial extension testing, catheter-based blood pressure, and wire myography, yielding the time evolution of arterial thickening, stiffening, and vasoactive dysfunction required to fit G&R constitutive parameters. Results: Excellent agreement was observed between model predictions and observed patterns of arterial thickening, stiffening, and dysfunction among all CoA groups. For example, predicted vascular impairment was not significantly different from empirical observations via wire myography (p-value > 0.13). Specifically, 48% and 45% impairment was observed in smooth muscle contraction and endothelial-dependent relaxation, respectively, which were accurately predicted using the G&R model. Conclusions: The resulting G&R model, for the first time, allows for prediction of hypertension precursors at neonatal ages that is currently challenging to examine in preclinical models. These findings provide a validated computational tool for prediction of persistent arterial dysfunction and identification of revised severity-duration thresholds that may ultimately avoid hypertension from CoA.

3.
Front Cardiovasc Med ; 10: 1162731, 2023.
Article En | MEDLINE | ID: mdl-37293290

Introduction: Congenital heart disease is the leading cause of death related to birth defects and affects 1 out of every 100 live births. Induced pluripotent stem cell technology has allowed for patient-derived cardiomyocytes to be studied in vitro. An approach to bioengineer these cells into a physiologically accurate cardiac tissue model is needed in order to study the disease and evaluate potential treatment strategies. Methods: To accomplish this, we have developed a protocol to 3D-bioprint cardiac tissue constructs comprised of patient-derived cardiomyocytes within a hydrogel bioink based on laminin-521. Results: Cardiomyocytes remained viable and demonstrated appropriate phenotype and function including spontaneous contraction. Contraction remained consistent during 30 days of culture based on displacement measurements. Furthermore, tissue constructs demonstrated progressive maturation based on sarcomere structure and gene expression analysis. Gene expression analysis also revealed enhanced maturation in 3D constructs compared to 2D cell culture. Discussion: This combination of patient-derived cardiomyocytes and 3D-bioprinting represents a promising platform for studying congenital heart disease and evaluating individualized treatment strategies.

4.
Tissue Eng Part A ; 29(15-16): 413-423, 2023 08.
Article En | MEDLINE | ID: mdl-37130041

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0-4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.


Biocompatible Materials , Nanofibers , Biocompatible Materials/pharmacology , Biocompatible Materials/chemistry , Tissue Engineering , Nanofibers/chemistry , Polyurethanes/pharmacology , Endothelial Cells , Magnetic Phenomena , Coated Materials, Biocompatible/chemistry
5.
Bioengineering (Basel) ; 10(4)2023 Mar 28.
Article En | MEDLINE | ID: mdl-37106611

Elastic laminae, an elastin-based, layered extracellular matrix structure in the media of arteries, can inhibit leukocyte adhesion and vascular smooth muscle cell proliferation and migration, exhibiting anti-inflammatory and anti-thrombogenic properties. These properties prevent inflammatory and thrombogenic activities in the arterial media, constituting a mechanism for the maintenance of the structural integrity of the arterial wall in vascular disorders. The biological basis for these properties is the elastin-induced activation of inhibitory signaling pathways, involving the inhibitory cell receptor signal regulatory protein α (SIRPα) and Src homology 2 domain-containing protein tyrosine phosphatase 1 (SHP1). The activation of these molecules causes deactivation of cell adhesion- and proliferation-regulatory signaling mechanisms. Given such anti-inflammatory and anti-thrombogenic properties, elastic laminae and elastin-based materials have potential for use in vascular reconstruction.

6.
J Vis Exp ; (179)2022 01 06.
Article En | MEDLINE | ID: mdl-35068481

The endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function. Various groups have evaluated the functionality of endothelial cells derived from human peripheral blood with a focus on endothelial progenitor cells derived from hematopoietic stem cells or mature blood outgrowth endothelial cells (or endothelial colony-forming cells). These cells provide an autologous resource for therapeutics and disease modeling. Xenogeneic cells may provide an alternative source of therapeutics due to their availability and homogeneity achieved by using genetically similar animals raised in similar conditions. Hence, a robust protocol for the isolation and expansion of highly proliferative blood outgrowth endothelial cells from porcine peripheral blood has been presented. These cells can be used for numerous applications such as cardiovascular tissue engineering, cell therapy, disease modeling, drug screening, studying endothelial cell biology, and in vitro co-cultures to investigate inflammatory and coagulation responses in xenotransplantation.


Atherosclerosis , Endothelial Progenitor Cells , Animals , Blood Coagulation , Cell- and Tissue-Based Therapy , Swine , Tissue Engineering/methods
7.
Tissue Eng Part B Rev ; 28(5): 1067-1092, 2022 10.
Article En | MEDLINE | ID: mdl-34693761

The endothelium is a critical mediator of homeostasis on blood-contacting surfaces in the body, serving as a selective barrier to regulate processes such as clotting, immune cell adhesion, and cellular response to fluid shear stress. Implantable cardiovascular devices, including stents, vascular grafts, heart valves, and left ventricular assist devices, are in direct contact with circulating blood and carry a high risk for platelet activation and thrombosis without a stable endothelial cell (EC) monolayer. Development of a healthy endothelium on the blood-contacting surface of these devices would help ameliorate risks associated with thrombus formation and eliminate the need for long-term antiplatelet or anticoagulation therapy. Although ECs have been seeded onto or recruited to these blood-contacting surfaces, most ECs are lost upon exposure to shear stress due to circulating blood. Many investigators have attempted to generate a stable EC monolayer by improving EC adhesion using surface modifications, material coatings, nanofiber topology, and modifications to the cells. Despite some success with enhanced EC retention in vitro and in animal models, no studies to date have proven efficacious for routinely creating a stable endothelium in the clinical setting. This review summarizes past and present techniques directed at improving the adhesion of ECs to blood-contacting devices. Impact statement Clinical success of blood-contacting devices such as vascular grafts, stents, and heart valves has remained limited by postimplantation problems, including thrombosis and loss of patency. Without a stable endothelial cell (EC) monolayer, blood-contacting devices are at risk for platelet activation and thrombosis. Methods to improve EC adhesion on these devices have not translated to long-term in vivo success, as many ECs are lost after exposure to circulating blood. In this study, we summarize methods to improve EC adhesion and retention. Successful endothelialization of blood-contacting devices may improve patient outcomes after device implantation and limit the need for long-term antiplatelet or anticoagulation therapy.


Endothelial Cells , Thrombosis , Animals , Cell Adhesion , Blood Vessel Prosthesis , Thrombosis/prevention & control , Endothelium , Anticoagulants/pharmacology
8.
Cardiovasc Eng Technol ; 10(1): 80-94, 2019 03.
Article En | MEDLINE | ID: mdl-30311149

PURPOSE: Tissue engineered heart valves (TEHV) are being investigated to address the limitations of currently available valve prostheses. In order to advance a wide variety of TEHV approaches, the goal of this study was to develop a cardiac valve bioreactor system capable of conditioning living valves with a range of hydrodynamic conditions as well as capable of assessing hydrodynamic performance to ISO 5840 standards. METHODS: A bioreactor system was designed based on the Windkessel approach. Novel features including a purpose-built valve chamber and pressure feedback control were incorporated to maintain asepsis while achieving a range of hydrodynamic conditions. The system was validated by testing hydrodynamic conditions with a bioprosthesis and by operating with cell culture medium for 4 weeks and living cells for 2 weeks. RESULTS: The bioreactor system was able to produce a range of pressure and flow conditions from static to resting adult left ventricular outflow tract to pathological including hypertension. The system operated aseptically for 4 weeks and cell viability was maintained for 2 weeks. The system was also able to record the pressure and flow data needed to calculate effective orifice area and regurgitant fraction. CONCLUSIONS: We have developed a single bioreactor system that allows for step-wise conditioning protocols to be developed for each unique TEHV design as well as allows for hydrodynamic performance assessment.


Bioprosthesis , Bioreactors , Cell Culture Techniques/instrumentation , Heart Valve Prosthesis , Heart Valves/physiology , Tissue Engineering/instrumentation , Animals , Cell Survival , Equipment Design , Humans , Hydrodynamics , Mice , NIH 3T3 Cells , Prosthesis Design , Time Factors
9.
J Tissue Eng Regen Med ; 12(7): 1608-1620, 2018 07.
Article En | MEDLINE | ID: mdl-29749108

Fixed pericardial tissue is commonly used for commercially available xenograft valve implants, and has proven durability, but lacks the capability to remodel and grow. Decellularized porcine pericardial tissue has the promise to outperform fixed tissue and remodel, but the decellularization process has been shown to damage the collagen structure and reduce mechanical integrity of the tissue. Therefore, a comparison of uniaxial tensile properties was performed on decellularized, decellularized-sterilized, fixed, and native porcine pericardial tissue versus native valve leaflet cusps. The results of non-parametric analysis showed statistically significant differences (p < .05) between the stiffness of decellularized versus native pericardium and native cusps as well as fixed tissue, respectively; however, decellularized tissue showed large increases in elastic properties. Porosity testing of the tissues showed no statistical difference between decellularized and decell-sterilized tissue compared with native cusps (p > .05). Scanning electron microscopy confirmed that valvular endothelial and interstitial cells colonized the decellularized pericardial surface when seeded and grown for 30 days in static culture. Collagen assays and transmission electron microscopy analysis showed limited reductions in collagen with processing; yet glycosaminoglycan assays showed great reductions in the processed pericardium relative to native cusps. Decellularized pericardium had comparatively low mechanical properties among the groups studied; yet the stiffness was comparatively similar to the native cusps and demonstrated a lack of cytotoxicity. Suture retention, accelerated wear, and hydrodynamic testing of prototype decellularized and decell-sterilized valves showed positive functionality. Sterilized tissue could mimic valvular mechanical environment in vitro, therefore making it a viable potential candidate for off-the-shelf tissue-engineered valvular applications.


Biocompatible Materials/chemistry , Bioprosthesis , Heart Valve Prosthesis , Materials Testing , Pericardium/chemistry , Animals , Cells, Cultured , Swine , Tissue Engineering
10.
Tissue Eng Part A ; 24(13-14): 1157-1166, 2018 07.
Article En | MEDLINE | ID: mdl-29431053

Incomplete endothelialization of intracoronary stents has been associated with stent thrombosis and recurrent symptoms, whereas prolonged use of dual antiplatelet therapy increases bleeding-related adverse events. Facilitated endothelialization has the potential to improve clinical outcomes in patients who are unable to tolerate dual antiplatelet therapy. The objective of this study was to demonstrate the feasibility of magnetic cell capture to rapidly endothelialize intracoronary stents in a large animal model. A novel stent was developed from a magnetizable duplex stainless steel (2205 SS). Polylactic-co-glycolic acid and magnetite (Fe3O4) were used to synthesize biodegradable superparamagnetic iron oxide nanoparticles, and these were used to label autologous blood outgrowth endothelial cells. Magnetic 2205 SS and nonmagnetic 316L SS control stents were implanted in the coronary arteries of pigs (n = 11), followed by intracoronary delivery of magnetically labeled cells to 2205 SS stents. In this study, we show extensive endothelialization of magnetic 2205 SS stents (median 98.4% cell coverage) within 3 days, whereas the control 316L SS stents exhibited significantly less coverage (median 48.9% cell coverage, p < 0.0001). This demonstrates the ability of intracoronary delivery of magnetic nanoparticle labeled autologous endothelial cells to improve endothelialization of magnetized coronary stents within 3 days of implantation.


Endothelial Cells/cytology , Metals/chemistry , Nanoparticles/chemistry , Stents , Animals , Endothelial Cells/drug effects , Endothelial Cells/ultrastructure , Female , Nanoparticles/ultrastructure , Phenotype , Stainless Steel/pharmacology , Swine
11.
PLoS One ; 12(8): e0181614, 2017.
Article En | MEDLINE | ID: mdl-28763463

Current research on valvular heart repair has focused on tissue-engineered heart valves (TEHV) because of its potential to grow similarly to native heart valves. Decellularized xenografts are a promising solution; however, host recellularization remains challenging. In this study, decellularized porcine aortic valves were implanted into the right ventricular outflow tract (RVOT) of sheep to investigate recellularization potential. Porcine aortic valves, decellularized with sodium dodecyl sulfate (SDS), were sterilized by supercritical carbon dioxide (scCO2) and implanted into the RVOT of five juvenile polypay sheep for 5 months (n = 5). During implantation, functionality of the valves was assessed by serial echocardiography, blood tests, and right heart pulmonary artery catheterization measurements. The explanted valves were characterized through gross examination, mechanical characterization, and immunohistochemical analysis including cell viability, phenotype, proliferation, and extracellular matrix generation. Gross examination of the valve cusps demonstrated the absence of thrombosis. Bacterial and fungal stains were negative for pathogenic microbes. Immunohistochemical analysis showed the presence of myofibroblast-like cell infiltration with formation of new collagen fibrils and the existence of an endothelial layer at the surface of the explant. Analysis of cell phenotype and morphology showed no lymphoplasmacytic infiltration. Tensile mechanical testing of valve cusps revealed an increase in stiffness while strength was maintained during implantation. The increased tensile stiffness confirms the recellularization of the cusps by collagen synthesizing cells. The current study demonstrated the feasibility of the trans-species implantation of a non-fixed decellularized porcine aortic valve into the RVOT of sheep. The implantation resulted in recellularization of the valve with sufficient hemodynamic function for the 5-month study. Thus, the study supports a potential role for use of a TEHV for the treatment of valve disease in humans.


Aortic Valve/pathology , Heart Valve Prosthesis , Heart Ventricles/pathology , Animals , Aortic Valve/surgery , Biomechanical Phenomena , Carbon Dioxide/chemistry , Cell Proliferation , Cell Survival , Echocardiography , Extracellular Matrix/metabolism , Female , Heart Ventricles/surgery , Hemodynamics , Humans , Male , Phenotype , Prosthesis Design , Pulmonary Valve/pathology , Sheep , Swine , Tensile Strength , Tissue Engineering/methods , Transplantation, Heterologous
12.
J Cardiothorac Surg ; 12(1): 56, 2017 Jul 17.
Article En | MEDLINE | ID: mdl-28716099

BACKGROUND: The xenoantigenicity of porcine bioprosthetic valves is implicated as an etiology leading to calcification and subsequent valve failure. Decellularization of porcine valves theoretically could erase the antigenicity of the tissue leading to more durable prosthetic valves, but the effectiveness of decellularization protocols in regard to completely removing antigens has yet to be verified. Our hypothesis was that decellularization would remove the more abundant α-gal antigens but not remove all the non α-gal antigens, which could mount a response. METHODS: Porcine aortic valves were decellularized with 1% sodium dodecyl sulfate for 4 days. Decellularized cusps were evaluated for α-gal epitopes by ELISA. To test for non α-gal antigens, valves were implanted into sheep. Serum was obtained from the sheep preoperatively and 1 week, 1 month, and 2 months postoperatively. This serum was utilized for anti-porcine antibody staining and for quantification of anti-pig IgM and IgG antibodies and complement. RESULTS: Decellularized porcine cusps had 2.8 ± 2.0% relative α-gal epitope as compared to fresh porcine aortic valve cusps and was not statistically significantly different (p = 0.4) from the human aortic valve cusp which had a 2.0 ± 0.4% relative concentration. Anti-pig IgM and IgG increased postoperatively from baseline levels. Preoperatively anti-pig IgM was 27.7 ± 1.7 µg/mL and it increased to 71.9 ± 12.1 µg/mL average of all time points postoperatively (p = 0.04). Preoperatively anti-pig IgG in sheep serum was 44.9 ± 1.5 µg/mL and it increased to 72.6 ± 6.0 µg/mL average of all time points postoperatively (p = 0.01). There was a statistically significant difference (p = 0.00007) in the serum C1q concentration before valve implantation (2.5 ± 0.2 IU/mL) and at averaged time points after valve implantation (5.3 ± 0.3 IU/mL). CONCLUSIONS: Decellularization with 1% sodium dodecyl sulfate does not fully eliminate non α-gal antigens; however, significant reduction in α-gal presence on decellularized cusps was observed. Clinical implications of the non α-gal antigenic response are yet to be determined. As such, evaluation of any novel decellularized xenografts must include rigorous antigen testing prior to human trials.


Aortic Valve/surgery , Bioprosthesis , Calcinosis/immunology , Graft vs Host Disease/immunology , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Immunity, Humoral , Animals , Bioprosthesis/adverse effects , Calcinosis/etiology , Disease Models, Animal , Graft vs Host Disease/complications , Prosthesis Failure , Sheep , Sus scrofa , Swine , Transplantation, Heterologous
13.
J Magn Magn Mater ; 427: 100-104, 2017 Apr 01.
Article En | MEDLINE | ID: mdl-28286359

Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

14.
JACC Basic Transl Sci ; 2(1): 71-84, 2017 Feb.
Article En | MEDLINE | ID: mdl-28337488

OBJECTIVE: The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. BACKGROUND: Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. METHODS: Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. RESULTS: Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). CONCLUSIONS: Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. SUMMARY: Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues.

15.
J Vis Exp ; (116)2016 10 26.
Article En | MEDLINE | ID: mdl-27805589

Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.


Prosthesis Design , Stents , Aorta , Equipment Design , Humans , Metals , Nanofibers , Polyurethanes , Transplants
16.
Ann Thorac Surg ; 101(2): 667-74, 2016 Feb.
Article En | MEDLINE | ID: mdl-26453425

BACKGROUND: Decellularized heart valves are emerging as a potential alternative to current bioprostheses for valve replacement. Whereas techniques of decellularization have been thoroughly examined, terminal sterilization techniques have not received the same scrutiny. METHODS: This study evaluated low-dose gamma irradiation as a sterilization method for decellularized heart valves. Incubation of valves and transmission electron microscopy evaluation after different doses of gamma irradiation were used to determine the optimal dose of gamma irradiation. Quantitative evaluation of mechanical properties was done by tensile mechanical testing of isolated cusps. Sterilized decellularized heart valves were tested in a sheep model (n = 3 [1 at 1,500 Gy and 2 at 3,000 Gy]) of pulmonary valve replacement. RESULTS: Valves sterilized with gamma radiation between 1,000 Gy and 3,000 Gy were found to be optimal with in vitro testing. However, in vivo testing showed deteriorating valve function within 2 months. On explant, the valve with 1,500 Gy gamma irradiation showed signs of endocarditis with neutrophils on hematoxylin and eosin staining, and positive gram stain resembling streptococcus infection. The 3,000 Gy valves had no evidence of infection, but the hematoxylin and eosin staining showed evidence of wound remodeling with macrophages and fibroblasts. Tensile strength testing showed decreased strength (0 Gy: 2.53 ± 0.98 MPa, 1,500 Gy: 2.03 ± 1.23 MPa, and 3,000 Gy: 1.26 ± 0.90 MPa) with increasing levels of irradiation. CONCLUSIONS: Low-dose gamma irradiation does not maintain the mechanical integrity of valves, and the balance between sterilization and damage may not be able to be achieved with gamma irradiation. Other methods of terminal sterilization must be pursued and evaluated.


Bioprosthesis , Gamma Rays , Heart Valve Prosthesis , Heart Valves/injuries , Heart Valves/radiation effects , Sterilization/methods , Animals , Heart Valves/cytology , In Vitro Techniques , Radiation Dosage , Sheep , Swine
17.
J Vis Exp ; (105): e53099, 2015 Oct 19.
Article En | MEDLINE | ID: mdl-26554870

Targeted delivery of cells and therapeutic agents would benefit a wide range of biomedical applications by concentrating the therapeutic effect at the target site while minimizing deleterious effects to off-target sites. Magnetic cell targeting is an efficient, safe, and straightforward delivery technique. Superparamagnetic iron oxide nanoparticles (SPION) are biodegradable, biocompatible, and can be endocytosed into cells to render them responsive to magnetic fields. The synthesis process involves creating magnetite (Fe3O4) nanoparticles followed by high-speed emulsification to form a poly(lactic-co-glycolic acid) (PLGA) coating. The PLGA-magnetite SPIONs are approximately 120 nm in diameter including the approximately 10 nm diameter magnetite core. When placed in culture medium, SPIONs are naturally endocytosed by cells and stored as small clusters within cytoplasmic endosomes. These particles impart sufficient magnetic mass to the cells to allow for targeting within magnetic fields. Numerous cell sorting and targeting applications are enabled by rendering various cell types responsive to magnetic fields. SPIONs have a variety of other biomedical applications as well including use as a medical imaging contrast agent, targeted drug or gene delivery, diagnostic assays, and generation of local hyperthermia for tumor therapy or tissue soldering.


Drug Delivery Systems/methods , Magnetite Nanoparticles/chemistry , Animals , Contrast Media , Humans , Lactic Acid/chemistry , Polyglycolic Acid/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer
18.
J Vis Exp ; (103)2015 Sep 18.
Article En | MEDLINE | ID: mdl-26436434

Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.


Cytological Techniques/instrumentation , Endothelial Cells/cytology , Magnetite Nanoparticles , Magnets , Stents , Animals , Computer-Aided Design , Cytological Techniques/methods , Equipment Design , Finite Element Analysis , Magnetics/instrumentation , Magnetics/methods , Swine
19.
Ann Biomed Eng ; 42(12): 2416-24, 2014 Dec.
Article En | MEDLINE | ID: mdl-25138164

Rapid healing of vascular stents is important for avoiding complications associated with stent thrombosis, restenosis, and bleeding related to antiplatelet drugs. Magnetic forces can be used to capture iron-labeled endothelial cells immediately following stent implantation, thereby promoting healing. This strategy requires the development of a magnetic stent that is biocompatible and functional. We designed a stent from the weakly ferromagnetic 2205 stainless steel using finite element analysis. The final design exhibited a principal strain below the fracture limit of 30% during crimping and expansion. Ten stents were fabricated and validated experimentally for fracture resistance. Another 10 stents magnetized with a neodymium magnet showed a magnetic field in the range of 100-750 mG. The retained magnetism was sufficiently strong to capture magnetically-labeled endothelial cells on the stent surfaces during in vitro studies. Magnetically-labeled endothelial cell capture was also verified in vivo after 7 days following coronary implantation in 4 pigs using histological analysis. Images of the stented blood vessels showed uniform endothelium formation on the stent surfaces. In conclusion, we have designed a ferromagnetic bare metal stent from 2205 stainless steel that is functional, biocompatible, and able to capture and retain magnetically-labeled endothelial cells in order to promote rapid stent healing.


Coronary Vessels , Endothelial Cells , Stents , Angioplasty, Balloon, Coronary , Animals , Coronary Vessels/anatomy & histology , Equipment Design , Ferric Compounds/chemistry , Magnetic Phenomena , Materials Testing , Metal Nanoparticles/chemistry , Microscopy, Fluorescence , Neodymium , Stainless Steel , Swine
20.
Am J Physiol Heart Circ Physiol ; 303(12): H1446-58, 2012 Dec 15.
Article En | MEDLINE | ID: mdl-23064833

Myocardial ischemia (MI) activates innate cardioprotective mechanisms, enhancing cardiomyocyte tolerance to ischemia. Here, we report a MI-activated liver-dependent mechanism for myocardial protection. In response to MI in the mouse, hepatocytes exhibited 6- to 19-fold upregulation of genes encoding secretory proteins, including α-1-acid glycoprotein (AGP)2, bone morphogenetic protein-binding endothelial regulator (BMPER), chemokine (C-X-C motif) ligand 13, fibroblast growth factor (FGF)21, neuregulin (NRG)4, proteoglycan 4, and trefoil factor (TFF)3. Five of these proteins, including AGP2, BMPER, FGF21, NRG4, and TFF3, were identified as cardioprotective proteins since administration of each protein significantly reduced the fraction of myocardial infarcts (37 ± 9%, 34 ± 7%, 32 ± 8%, 39 ± 6%, and 31 ± 7%, respectively, vs. 48 ± 7% for PBS at 24 h post-MI). The serum level of the five proteins elevated significantly in association with protein upregulation in hepatocytes post-MI. Suppression of a cardioprotective protein by small interfering (si)RNA-mediated gene silencing resulted in a significant increase in the fraction of myocardial infarcts, and suppression of all five cardioprotective proteins with siRNAs further intensified myocardial infarction. While administration of a single cardioprotective protein mitigated myocardial infarction, administration of all five proteins furthered the beneficial effect, reducing myocardial infarct fractions from PBS control values from 46 ± 6% (5 days), 41 ± 5% (10 days), and 34 ± 4% (30 days) to 35 ± 5%, 28 ± 5%, and 24 ± 4%, respectively. These observations suggest that the liver contributes to cardioprotection in MI by upregulating and releasing protective secretory proteins. These proteins may be used for the development of cardioprotective agents.


Carrier Proteins/metabolism , Fibroblast Growth Factors/metabolism , Liver/metabolism , Mucins/metabolism , Myocardial Ischemia/metabolism , Up-Regulation/physiology , Animals , Coronary Stenosis/complications , Disease Models, Animal , Female , Hepatocytes/drug effects , Hepatocytes/metabolism , Hepatocytes/pathology , Liver/drug effects , Liver/pathology , Male , Mice , Mice, Inbred C57BL , Myocardial Ischemia/etiology , Myocardial Ischemia/pathology , Neuregulins/metabolism , Orosomucoid/metabolism , RNA, Small Interfering/pharmacology , Time Factors , Trefoil Factor-3 , Up-Regulation/drug effects
...